Two machines that look similar, do opposite jobs, and are usually bought together. This guide explains what each one does, where the boundary sits, and how to specify both without over-buying.
Key takeaways
- A magnetizer drives a hard magnetic material past saturation so it retains remanent flux.
- A demagnetizer applies a field that decays, walking the material around ever-smaller hysteresis loops toward zero.
- In a capacitive discharge magnetizer, energy is stored in a capacitor bank and released in one short pulse.
- The field the part sees is the product of the power supply and the coil wrapped around it.
Why the Pair Is Usually Specified Together
A magnetizer and a demagnetizer are the same power electronics driving the same kind of coil, in two different regimes. The magnetizer pushes a field strong enough to take a hard magnetic material past saturation, so that when the field is removed the material keeps a remanent flux. The demagnetizer does the reverse: it applies a field that decays in a controlled way, walking the material around smaller and smaller hysteresis loops until the residual flux is close enough to zero for the next process step.
Because the hardware overlaps so heavily, most production lines end up buying both from the same source. The magnetizer sets the magnetic state the product is sold with; the demagnetizer removes that state again when a part has to be reworked, machined, welded, inspected or scrapped. Buying them as a pair is not a packaging convenience — it means one coil design language, one control philosophy and one spare-parts list for the whole cell.
What a Magnetizer Does
A magnetizer is specified by the magnetic field it can produce inside the working volume of its coil, and by how long it can keep doing that. Those two numbers pull against each other: field strength comes from current and turns, and both of those generate heat. This is the reason magnetizer design is largely a thermal problem dressed up as an electrical one.
In a capacitive discharge magnetizer, energy is stored in a capacitor bank and released into the coil in a single short pulse. Stored energy follows the familiar relationship E = ½CV², so the field is set mainly by charging voltage and bank capacitance, and the pulse is short enough that the coil does not have time to overheat. This is the standard approach for high-coercivity materials such as sintered NdFeB, where a slow ramp would simply not reach saturation before the material’s own coercivity fights back.
A direct-current magnetizer works differently: it drives a steady current through the coil for a defined dwell time. The field is lower and the cycle is longer, but the field is also flatter across the working volume and easier to hold. For lower-coercivity materials, for large assemblies, and for cases where the magnetizing step is part of a slow manual operation, DC is often the more practical choice.
A third family, the permanent-magnet magnetizer, uses fixed rare-earth magnets in the fixture rather than a powered coil. There is no power supply and no cooling, and the field is whatever the fixture geometry produces. These are used where the required field is modest and the part geometry repeats exactly — a classic example being the small multi-pole rings used in sensors and encoders.
What a Demagnetizer Does
A demagnetizer is not simply a magnetizer run backwards at low power. To leave a part demagnetized, the applied field has to reverse polarity repeatedly while its amplitude falls, so that the material’s operating point spirals inward toward the origin of the B–H curve. A single weak pulse does not do this; it just leaves a different, smaller remanence.
In practice this is achieved either by an AC field that is ramped down, or by a sequence of decaying pulses of alternating polarity. Both approaches need the part to be inside the field long enough to complete the spiral, which is why demagnetizing is usually slower per part than magnetizing. Where throughput matters, the demagnetizer is sized on cycle count rather than on peak field.
Two applications dominate. The first is rework and correction: a rotor that failed its flux check, a sensor that was magnetized in the wrong orientation, a batch that was exposed to a fixture field by accident. The second is process hygiene: parts that are about to be machined, welded or measured cannot carry stray flux, because chips will cling to them and measuring instruments will read a field that belongs to the part rather than to the process. A demagnetizer for assembled parts and tooling addresses both cases, and is the reason demagnetizing capacity is usually specified as a percentage of magnetizing capacity rather than as a standalone number.
Where the Boundary Actually Sits
The practical question is not “which machine do I need” but “which state does the next process step require”. Three patterns cover most production lines:
- Magnetize only. The part is magnetized at the end of the line and shipped that way. Common for finished magnets, speaker assemblies and encoder rings.
- Demagnetize only. The incoming part arrives already magnetized and has to be neutralized before machining or assembly. Common in motor and instrument manufacturing, where purchased magnets arrive in a magnetized state.
- Both, in sequence. The part is magnetized, tested, and — if it fails — demagnetized and returned to the start of the loop. This is the pattern on automated rotor lines, and it is the one that most often exposes a badly matched pair of machines.
The two machines are often quoted together, but they solve opposite problems. The table below is the fastest way to decide which one a given station needs.
| Magnetizer | Demagnetizer | |
|---|---|---|
| Purpose | Raise a part above saturation so it holds a defined field | Drive a part below its residual level, usually to near zero |
| Field applied | Several times Hcj, shaped by the fixture | Decaying AC field, or a reverse pulse followed by decay |
| Typical equipment | Capacitor-discharge impulse unit + fixture | AC demagnetizing tunnel, coil, or reverse-pulse mode on the same unit |
| When you need it | New magnets, post-assembly rotors, sensor targets | Incoming inspection, rework, tool handling, scrap preparation |
| Failure if omitted | Part reads low flux and fails torque or sensitivity targets | Parts stick, attract swarf, or cannot be handled or assembled |
| Verification | Total flux (saturation) + surface field (orientation) | Residual field below a stated threshold, measured the same way |
The Coil Matters as Much as the Power Supply
A common specification mistake is to size the power supply and treat the coil as an accessory. In reality the field the part sees is the product of the power supply and the coil or fixture wrapped around it. A large bank driving a coil that does not fit the part produces a strong field somewhere other than where it is needed, and the result is a part that reads well on a test bench but is magnetized unevenly in service.
Three properties of the fixture decide the outcome. The first is working volume: the region inside which the field is uniform enough for the application. The second is pole geometry: whether the field is applied across the part, around it, or as a defined sequence of poles. The third is cooling path: how heat leaves the coil, which determines whether the line can run continuously or has to pause between cycles.
For open coils handling many small parts, a water-cooled solenoid is the usual answer. For rotor and ring work, a multi-pole fixture that writes the pole pattern radially around the bore is the usual answer. For prototype and low-volume work, an interchangeable coil set is often more economical than a dedicated fixture per part number.
How to Prove the Result
Neither machine is worth much without a way to measure what it produced. Two instruments cover most of the requirement:
- A fluxmeter with a search coil integrates the voltage induced when the part is withdrawn from the coil, and reports total flux in milliwebers. It answers the question “is this part magnetized to the level the drawing calls for”, and it is the instrument that automated lines use for pass-fail decisions.
- A teslameter with a Hall probe measures flux density at a point. It answers a different question “what is the field here”, which is what you need when checking a gap, a pole face or a leakage path rather than a whole part.
Both instruments have to be calibrated, and the calibration has to cover the working range rather than a single point. A fluxmeter calibrated at one range and used at another will produce a pass-fail decision that is repeatable but wrong, which is worse than a noisy one.
Where the line runs at production rate, the measurement moves into the machine. An automated magnetizing and testing system closes the loop by reading flux immediately after the pulse, deciding pass or fail against a recipe, and routing the part accordingly. The value is not only speed: it is that every part carries a recorded result, which is what automotive and medical customers ask for during audit.
Six Selection Mistakes Worth Avoiding
- Sizing on peak field alone. A machine that reaches the required field once, cold, may not reach it on the thousandth cycle. Ask for the field at working temperature, at the specified duty cycle.
- Ignoring duty cycle. The duty cycle, not the peak rating, determines whether the coil survives a shift. It also determines the chiller requirement.
- Treating demagnetizing as an afterthought. If the line has a rework path, the demagnetizer’s cycle time becomes the bottleneck in that path, and it is usually discovered late.
- Buying a fixture per part number. Adjustable or modular fixtures cost more up front and less over the life of the line, unless the part mix really is fixed.
- Specifying measurement separately from magnetizing. If flux checking is a separate manual step, the data is not attached to the part and the audit trail has a gap.
- Forgetting residual field on the tooling. Fixtures and handling tools become magnetized over time and start to affect the parts they touch. A periodic demagnetizing routine for tooling is cheaper than the defect it prevents.
Frequently Asked Questions
Are magnetizers & demagnetizers normally sold as a matched pair?
Not always, but they are usually specified together because they share coil designs and controls. A matched pair simplifies spares and operator training, and it removes the argument about which machine is responsible when a part reads out of tolerance.
Can one machine do both jobs?
Some impulse magnetizers can be configured to run a decaying alternating sequence and therefore demagnetize, but the cycle is usually slower and the result less clean than a dedicated unit. For occasional rework it is an acceptable compromise; for a routine demagnetizing step in the process it is not.
How do I know the part is fully demagnetized?
Measure it. The usual acceptance criterion is a residual flux density below a threshold agreed with the customer, checked with a Hall probe at the points where stray field matters. “It feels like it is not sticking to the fixture any more” is not a criterion.
Does demagnetizing damage the magnet?
A correctly performed demagnetizing cycle does not. Repeated exposure to fields well above the material’s coercivity can, so the demagnetizer’s field should be matched to the parts it will see rather than specified at the maximum the machine can produce.
What information do I need before requesting a quote?
Material and grade, part geometry and drawing, the magnetic state required at the end of the step, the cycle time the line allows, the supply voltage available, and whether cooling water is present. With those six items a coil and a power supply can be sized; without them any quotation is a guess.
Where to Go Next
If the requirement is to set a magnetic state and hold it, start from the impulse range and work backwards to the fixture. If the requirement is to remove a state that is already there, start from the demagnetizer and size it on the rework volume rather than on the line rate. If both, specify them as one cell so that the coil, the controls and the measurement share a single design. Other guides on magnetizing and demagnetizing sit on our magnetizing guides index.