From One-at-a-Time to 8–10 Parts per Minute: Building a 100 % Inspection Line for a Canadian Magnet User
A Canadian manufacturer of compact magnetic assemblies buys pre-magnetized strontium ferrite cylinders in two formats — 8 mm in diameter, 5 mm and 15 mm in height — in tubes of 98 and 32 pieces, at roughly 700,000 parts a year. The problem was never the magnets. It was the handling.
The starting point: every magnet handled by hand
Every part was taken out of its tube by hand, fitted into the assembly, and checked on a bench fluxmeter only when someone suspected a problem. There was no 100 % inspection, because a 100 % inspection done by hand was not affordable in the cycle time available. Out-of-range magnets reached the assembly line, and the rejects were found downstream — after value had already been added.
Three things made the case harder than a typical sorting job:
- A very narrow acceptance window. The magnetic moment has to sit within about ±1.5 % of target — roughly three percent total width, the kind of window where the measurement method matters as much as the machine.
- A temperature-sensitive material. Strontium ferrite loses about 0.2 % of its moment per degree Celsius. In a workshop that swings by ±10 °C, the material alone moves ±2.0 % — wider than the entire window.
- A throughput target of 8–10 parts per minute, with automatic feeding, classification, sorting and data recording, so the operation could run without a dedicated inspector.
Our approach: measure first, then decide what the machine should be
Before quoting a configuration, we separated two questions that are usually mixed together.
What does the measuring station have to deliver? A Helmholtz-coil flux measurement with traceable calibration — not a hand-held gauge. We sized the coil around the two part volumes (0.251 cm³ and 0.754 cm³) and selected a coil whose uniform region covers the small part at 0.1 % and the large part at 0.3 %, so one coil and one interchangeable holder serve both formats.
What is the machine actually for? Not for measuring. For removing a manual handling operation while guaranteeing that no out-of-range part reaches assembly.
That reframing changed the proposal. Instead of selling an instrument with a feeder attached, we presented three configurations of the same line, so the customer could see what each increment of automation buys.
| Configuration | What it does | |
|---|---|---|
| A | Measure & sort | Tube loading, singulation, measurement, classification, three-way sorting |
| B | + correction | Adds closed-loop demagnetization of high parts and re-measurement |
| C | + in-line magnetizing | Adds a magnetizing station at the front of the line |
Why the customer chose the boldest option
Option C sounds like the most complex one. In fact it is the simplest process.
A magnetic moment is the product of three things: the material’s remanence, the part volume, and how fully the material is magnetized. If you buy parts magnetized to saturation and then trim the strong ones downward, you are solving one problem with two operations — full magnetization at the supplier, partial demagnetization at your plant, plus the transport risk of partially demagnetized parts in between.
If the parts arrive unmagnetized, each part can be charged directly to its target moment by partial saturation. Most parts then need no correction at all, and only the outliers receive a small trim. It also removes the supplier’s magnetizing cost from the chain and gives the customer control of the source.
Three engineering decisions inside that sequence matter more than the layout:
- One magazine for two formats. The two tube lengths differ by about 10 mm and a full tube weighs approximately the same in both formats — so a single, hand-carriable magazine design serves both, with an adjustable stop instead of a second magazine.
- A closed correction loop, not a one-shot trim. Every corrected part is measured again, and the line iterates if it is still outside the window. That is the difference between “sorting” and “correcting”.
- Temperature handled explicitly. The measuring station is specified with either a temperature-stabilized enclosure or per-part compensation. The accuracy figure we quote is always attached to the temperature condition it was obtained under.
What the customer gets
| Before | With the line | |
|---|---|---|
| Handling | One part at a time, by hand | Magazine loading, automatic singulation |
| Inspection | Sampling, or none | 100 % of incoming parts |
| Cycle | Manual, operator-paced | 6 s measuring cycle · 8–10 parts/min (5–8 with correction) |
| Out-of-range parts | Found downstream | Classified and diverted at the source |
| Data | Not recorded | Per-part moment, result and time stamp · CSV / MES export |
| Correction | Not possible | Closed-loop trim, verified by re-measurement |
The gain is not only speed. It is that the operation stops depending on an operator’s attention. The machine sees every part, decides, and records the decision — which is what makes a 100 % inspection claim defensible to the customer’s own quality department.
Three lessons we carry into every similar project
- Sell the handling, not the instrument. The real cost was the manual pick-and-place operation, not the absence of a fluxmeter. Once the proposal was framed that way, the technical discussion became much shorter.
- The temperature coefficient is often the binding constraint, not the instrument accuracy. A 0.5 % instrument means nothing if the workshop moves the material by 2 %.
- In-line magnetizing is usually presented as an extra. It is better presented as a simplification: charge to target, and most of the correction problem disappears before it starts.
Talk to us about your part, your window and your cycle time: sales001@jhhsmag.com