Tesla Meter
A Tesla meter measures the magnetic flux density of a field, so the strength and the direction of a magnet can be checked at the surface, in a gap, or anywhere a probe can reach.
What a Tesla Meter Does
A Tesla meter is an instrument that measures magnetic flux density — that is, how strong a field is at the point where the probe is held. In day-to-day use it answers a simple question: is the field present in the right place, pointing in the right direction, and at a level the part is meant to have. The reading can be taken at the surface of a magnet, in the air gap between parts, or in the space around an assembly, depending on the probe and the task. The instrument is often written as one word, teslameter, and both spellings refer to the same handheld or benchtop field measurement function.
Because it reads the field directly, the instrument is commonly used to confirm polarity as well as magnitude, so the north and south faces of a part are known before it is fitted. It is also used to check incoming material and finished parts against a reference, which makes it a practical tool for inspection and for sorting a batch, where parts outside an accepted range are separated from the rest.
The same instrument serves the laboratory and the shop floor. A bench reading helps when a design is being verified, while a portable unit lets the same check be repeated at a machine or on a production line, so the field on each part can be confirmed without taking it away from the process.
What It Does
- Measures magnetic flux density at the point where the probe is placed
- Confirms polarity, so the north and south faces of a part are known before assembly
- Checks the surface field of incoming material and of finished parts against a reference
- Supports sorting, so parts outside the accepted range can be separated from a batch
- Gives a quick bench or line-side reading for routine field verification
Design Considerations
- Probe type and geometry — the probe decides where the field can be reached, so a probe suited to surfaces, gaps or confined spaces is chosen for the job.
- Range and units — the meter is matched to the fields it will meet, so small fields and strong fields can both be read on a scale that is easy to interpret.
- Field direction — because the probe responds to the component of the field along its axis, the way it is oriented against the magnet is part of the measurement method.
- Reference and calibration — readings are compared against a known reference, so checks stay consistent from one part and one operator to the next.
- Working environment — temperature, handling and stray fields around the bench are taken into account so the reading reflects the part and not the surroundings.
Compatible Equipment
A measurement instrument is one part of a complete magnetizing and testing setup, so it is specified together with the equipment that produces, holds and cools the field, and with the machines that handle the parts.
- Magnetic fluxmeters — for total flux measurement with a test coil
- Automated magnetizing and testing systems — where field checks run in line
- 1200V impulse magnetizers — the magnetizing source whose output is verified
- Custom magnetizing coils and fixtures — the tooling that shapes the field being measured
- Industrial water chillers — cooling that keeps a magnetizing station repeatable
Related Pages
Other pages in this group:
Discuss Your Measurement Requirement
Tell us what you need to check — surface field, polarity, or a sorting limit on a batch — and our engineers will suggest a measurement setup that fits the job.
Ready to check the field on your parts?
Send us the part, the field you need to confirm and where the check has to happen. Our engineering team will reply with a proposal and a quotation.
REQUEST A QUOTE
Get a quotation for Tesla Meter
Tell us about your component, magnet material and production target. Our engineers review the requirement and reply with technical feasibility and a quotation.
- Reviewed by our own engineers, not a sales desk
- Send drawings, samples or a reference part
- No obligation — we quote only what fits your process
Prefer to talk it through? WhatsApp +86 188 6892 9496
Frequently asked questions
What does a Tesla meter actually read?
Surface flux density at the point where the probe sits, in tesla or millitesla. It reports the local field, not the total the component carries.
How is it different from a fluxmeter?
A fluxmeter integrates the whole part through a coil; a Tesla meter samples one spot. Run both when you need the total and the peak from the same batch.
Which probe suits our parts?
A transverse probe for flat faces and pole gaps, an axial probe for bores and recesses. Probe thickness is what limits how close you can measure to a small feature.
How do we pick a range?
Start from the highest field you expect and choose a range that keeps readings in its upper half, because resolution falls away near the bottom of any range.