Magnetic Measurement

Magnetic Fluxmeters

A magnetic flux meter measures how much magnetic flux a component carries after it has been magnetized. In a magnetizing process this is the number that tells you whether the job was done properly — the pole pattern may look right, but it is the measured flux that confirms the magnetizing pulse actually reached the material. JHHS MAG supplies magnetic flux measurement instruments as part of a complete magnetizing setup, so the result of every run can be checked rather than assumed.

Front panel of a digital magnetic flux meter with mWb display, six range settings and manual adjust control

JH-T500 Digital Fluxmeter

The JH-T500 is a digital fluxmeter for measuring the magnetic flux of magnetic products and permanent-magnet parts. It is used together with a test coil: the component is placed in the coil, the instrument is zeroed, and the flux the component carries is read from the display. It is the instrument that verifies a magnetizing result instead of leaving it to visual inspection.

Flux measurement and magnetization are two halves of one process. The magnetizer delivers the pulse and the magnetizing coil and fixture shape it; the JH-T500 reports what the component actually received. Because the reading responds to the coil and the pulse, the instrument is used both for setup work — confirming a coil or fixture change before a production run — and for checking parts during or after production.

The JH-T500 provides six selectable ranges, manual zero and manual drift adjustment, settable upper and lower limits with a corresponding indicator output for pass/fail indication, and an RS232 communication interface. It is compatible with a range of test coils, so the coil can be matched to the component being measured.

Technical Specifications

JH-T500 Digital Fluxmeter — six selectable ranges. The figures below are the published values for each range.

JH-T500 Digital Fluxmeter — range, accuracy, stability and input impedance
Range Effective range Accuracy Stability Input impedance
0.2 0.01–40 mWb ±1% better than ±0.01 mWb / 5 s 4 kΩ
0.5 0.01–40 mWb ±1% better than ±0.01 mWb / 5 s 10 kΩ
1 0.01–40 mWb ±1% better than ±0.01 mWb / 5 s 20 kΩ
2 0.01–40 mWb ±1% better than ±0.01 mWb / 5 s 40 kΩ
4 0.01–40 mWb ±1% better than ±0.01 mWb / 5 s 80 kΩ
8 0.01–40 mWb ±1% better than ±0.01 mWb / 5 s 160 kΩ

On a narrow screen the specification table scrolls horizontally inside its container. Range selection is covered under Operation Essentials below.

Key Features

  • Compatible with a range of test coils
  • Measures the magnetic flux of magnetic products / permanent-magnet parts
  • Manual zero and manual drift adjustment
  • Six selectable ranges
  • Settable upper and lower limits with corresponding indicator output (pass/fail indication)
  • RS232 communication interface

Operation Essentials

These points come from the instrument manual and describe how the JH-T500 is set up and read in normal use.

  • Warm-up. Switch the instrument on and allow 15 minutes of warm-up before it is used for measurement.
  • Drift adjustment. After warm-up, adjust the drift and wait until the drift is stable before testing. The reading is considered stable when the displayed value stays within ±0.01 mWb for 5 seconds. The drift has to be adjusted again after changing range.
  • Measurement sequence. Put the magnet into the test coil, press ADJUST to zero the display, then take the magnet out of the coil. The value shown at this point is the magnetic flux of that magnet.
  • MEASURE key. On any range, the measurement is taken by pressing the MEASURE key.
  • Coil connection. Connect one end of the signal cable to the test coil and the other end to the COIL INPUT connector on the rear panel. The two connectors are colour-coded black and red and may be swapped to suit the test requirement.
  • Reading and range. The reading should not exceed 40.00 mWb. If the reading is too high, select a larger range. Keeping the reading within a suitable part of the range improves the accuracy of product sorting.

Front Panel Operation & Probe Interface

Wide front panel of the digital fluxmeter showing probe sockets, controls and the digital Tesla readout
Wide front-panel layout of the JH-T500: probe sockets, range and unit selection, and the digital readout used for flux and surface-field measurement.

Applications

  • Magnetic flux measurement of permanent-magnet parts and other magnetic products, using a matched test coil
  • Verifying the result of a magnetizing cycle — confirming the outcome by measurement instead of by eye
  • Production sorting, using the settable upper and lower limits and the corresponding indicator output for pass/fail indication
  • Incoming and outgoing inspection of magnetized components
  • Checking repeatability across a batch, so a drift in the magnetizing result can be identified and traced

Request Specifications and a Quote

Tell us what you need to measure, the component and the flux level you expect, and how the component is presented to the test coil. We will come back with the right configuration and a quotation.

Request a Quote →

Magnetic Fluxmeter FAQs

What is the difference between a fluxmeter and a gaussmeter?

A fluxmeter integrates the voltage induced in a measuring coil to determine a change in magnetic flux linkage. With a defined coil and measurement procedure, it can support flux or magnetic moment measurements. A gaussmeter measures local magnetic flux density at a probe position. The appropriate instrument depends on the quantity specified for inspection.

Why does the measuring coil matter when selecting a fluxmeter?

The coil determines how the component’s magnetic field is coupled into the measurement. Its geometry, turns, calibration, and positioning must suit the part and inspection objective. A suitable instrument alone does not define the complete measurement system; the coil and test procedure must also be specified.

Can a flux measurement confirm the pole pattern of a multipole magnet?

Not by itself. An overall flux measurement may not identify an incorrectly positioned pole or a local field defect. When pole count, polarity sequence, or angular distribution is critical, a suitable field-distribution measurement should be included in the inspection plan.

Ready to discuss your magnetizing requirement?

Send us your component drawing, pole pattern and target magnetization. Our engineering team will reply with a configuration proposal and a quotation.

REQUEST A QUOTE

Get a quotation for Magnetic Fluxmeters

Tell us about your component, magnet material and production target. Our engineers review the requirement and reply with technical feasibility and a quotation.

  • Reviewed by our own engineers, not a sales desk
  • Send drawings, samples or a reference part
  • No obligation — we quote only what fits your process
Name

Prefer to talk it through? WhatsApp +86 188 6892 9496

Frequently asked questions

What does a fluxmeter actually measure?

Total flux through a search coil, reported as flux linkage in volt-seconds per turn. Divide it by the coil's turn-area and you have the average flux density carried by the part.

Fluxmeter or gaussmeter — which one do we need?

A fluxmeter integrates the whole component; a gaussmeter reads the field at a single point on its surface. Acceptance testing usually wants both, because total flux and local peaks can disagree.

Can the search coil be matched to our part?

Yes. Coils are wound to the part envelope so the sample sits inside the winding, which is what makes the reading repeatable between operators and between shifts.

How do we start an inquiry?

Send the part envelope, the flux target and the unit you report in. We come back with a coil and instrument combination that fits that measurement.